    Technical Data

    Rated Voltage Max:250VAC,50/60Hz

    Operating frequency: DC to 400Hz

    Rated currents:20~50A@40°C

    Hipot Rating :L-N 1450VDC  |  L/N-G 2000VAC/2250VDC

    Climatic category:-25°C~+85°C(25/85/21)

    Design corresponding to: UL1283, CSA C22.2 No.8, IEC/EN 60939,  CQC GB 15288/GB 15287-2008 

    Flammability corresponding to:UL 94V-0


    Typical Applications

    --Electrical and electronic equipment、Medical equipment、Building automation、Office automation and datacom equipment--

  • Parameters

    Technical Data

    Rated Voltage Max:250VAC,50/60Hz

    Operating frequency: DC to 400Hz

    Rated currents:20~50A@40°C

    Hipot Rating :L-N 1450VDC  |  L/N-G 2000VAC/2250VDC

    Climatic category:-25°C~+85°C(25/85/21)

    Design corresponding to: UL1283, CSA C22.2 No.8, IEC/EN 60939,  CQC GB 15288/GB 15287-2008 

    Flammability corresponding to:UL 94V-0


    Typical Applications

    --Electrical and electronic equipment、Medical equipment、Building automation、Office automation and datacom equipment--

Features 


--Designed 2 stage enhanced filtering to prevent the power supply may produce interference to the device.

--Various terminal options allow you to select the desired connection style.

--There are a variety of parts and combinations to meet different customer's EMC tests.

--Customized products according to customer's requirements.


Electrical schematic


Rule of Nomination 


YB21F1-10A-Q( R5)

||
|
|||

circuit
shell
-current
-output
optional
optional


Tabulates


Model No.Rated Current
@40°C

Terminal Options*

Leakage current

250V/50Hz

Electrical Schematic

Rated Voltage

(V)

Operating Frequency

(Hz)

YB21F1-25A25AQS-<0.8mAFig.1115/250V50/60Hz
YB21F1-30A30AQS-Fig.1
YB21F1-50A50AQS-Fig.1
YB21F2-25A25AQS-Fig.1
YB21F2-30A30AQS-Fig.1
YB21F2-50A50AQS-Fig.1
YB21F3-25A25AQS-Fig.1
YB21F3-30A30AQS-Fig.1
YB21F3-50A50AQS-Fig.1
YB22F1-25A25AQS-Fig.1
YB22F1-30A30AQS-Fig.1
YB22F1-50A50AQS-Fig.1
YB22F2-25A25AQS-Fig.1
YB22F2-30A30AQS-Fig.1
YB22F2-50A50AQS-Fig.1
YB22F3-25A25AQS-Fig.1
YB22F3-30A30AQS-Fig.1
YB22F3-50A50AQS-Fig.1
YB35F1-25A25AQS-Fig.1
YB35F1-30A30AQS-Fig.1
YB35F1-50A50AQS-Fig.1
YB35F2-25A25AQS-Fig.1
YB35F2-30A30AQS-Fig.1
YB35F2-50A50AQS-Fig.1
YB35F3-25A25AQS-Fig.1
YB35F3-30A30AQS-Fig.1
YB35F3-50A50AQS-Fig.1


Medical equipment


Model No.Rated Current
@40°C

Terminal Options

Medical equipment

5

Leakage current

 250V/50Hz

Electrical Schematic

Rated Voltage

(V)

Operating Frequency

(Hz)

YB21F1-25A-x(R5)25AQS-5<5μAFig.2115/250V50/60Hz
YB21F1-30A-x(R5)30AQS-5Fig.2
YB21F1-50A-x(R5)50AQS-5Fig.2
YB21F2-25A-x(R5)25AQS-5Fig.2
YB21F2-30A-x(R5)30AQS-5Fig.2
YB21F2-50A-x(R5)50AQS-5Fig.2
YB21F3-25A-x(R5)25AQS-5Fig.2
YB21F3-30A-x(R5)30AQS-5Fig.2
YB21F3-50A-x(R5)50AQS-5Fig.2
YB22F1-25A-x(R5)25AQS-5Fig.2
YB22F1-30A-x(R5)30AQS-5Fig.2
YB22F1-50A-x(R5)50AQS-5Fig.2
YB22F2-25A-x(R5)25AQS-5Fig.2
YB22F2-30A-x(R5)30AQS-5Fig.2
YB22F2-50A-x(R5)50AQS-5Fig.2
YB22F3-25A-x(R6)25AQS-5Fig.2
YB22F3-30A-x(R6)30AQS-5Fig.2
YB22F3-50A-x(R6)50AQS-5Fig.2
YB35F1-25A-x(R7)25AQS-5Fig.2
YB35F1-30A-x(R7)30AQS-5Fig.2
YB35F1-50A-x(R7)50AQS-5Fig.2
YB35F2-25A-x(R7)25AQS-5Fig.2
YB35F2-30A-x(R8)30AQS-5Fig.2
YB35F2-50A-x(R8)50AQS-5Fig.2
YB35F3-25A-x(R8)25AQS-5Fig.2
YB35F3-30A-x(R9)30AQS-5Fig.2
YB35F3-50A-x(R9)50AQS-5Fig.2




Mechanical Dimension




Insertion loss table(In 50ohm system according IEC/CISPR No.17)


--------common mode  -------differential mode

Industrial Enhanced Power Filter 21-22-35 Line 50A
Long press to look detail
Long by picture save/share
图片展示

WeChat Subscription

图片展示

Wechat

SHENZHEN YANBIXIN TECHNOLOGY CO.,LTD    TEL:+86-755-27147102/27147103

SHENZHEN YANBIXIN TECHNOLOGY CO.,LTD

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了