General purpose power supply filter 12 line below 30A

    Technical Data

    Rated Voltage Max:250VAC,50/60Hz

    Operating frequency: DC to 400Hz

    Rated currents:1~30A@40°C

    Hipot Rating:L-N 1450VDC  |  L/N-G 2000VAC/2250VDC

    Climatic category:-25°C~+85°C(25/85/21)

    Design corresponding to: UL1283, CSA C22.2 No.8, IEC/EN 60939,  CQC GB 15288/GB 15287-2008 

    Flammability corresponding to:UL 94V-0


    Typical Applications

    --Electrical and electronic equipment、Medical equipment、Datacom equipment、Office automation equipment--

  • Parameters

    Technical Data

    Rated Voltage Max:250VAC,50/60Hz

    Operating frequency: DC to 400Hz

    Rated currents:1~30A@40°C

    Hipot Rating:L-N 1450VDC  |  L/N-G 2000VAC/2250VDC

    Climatic category:-25°C~+85°C(25/85/21)

    Design corresponding to: UL1283, CSA C22.2 No.8, IEC/EN 60939,  CQC GB 15288/GB 15287-2008 

    Flammability corresponding to:UL 94V-0


    Typical Applications

    --Electrical and electronic equipment、Medical equipment、Datacom equipment、Office automation equipment--

Features


--The compact size can be applied to  various situations.

--YB12 filters are also available as two-stage filters(YB35) in noisy environmment . 

--There are a variety of parts and combinations to meet different customer's EMC tests 

--Customized products according to customer's requirements


Electrical schematic


Standard typeR5 type
Fig.1Fig.2



Rule of Nomination


YB12E4-10A-Q( R5)

||
|
|||

circuit
shell
-current
-output
optional
optional


Tabulates


Model No.Rated Current
@40°C

Terminal Options*

Bleeder resistor(optional)

Leakage current

250V/50Hz 

Electrical Schematic

Rated Voltage

(V)

Operating Frequency

(Hz)

YB12E4-1A1AQSW-<0.8mAFig.1115/250V50/60Hz
YB12E4-2A2AQSW-Fig.1
YB12E4-3A3AQSW-Fig.1
YB12E4-4A4AQSW-Fig.1
YB12E4-6A6AQSW-Fig.1
YB12E4-8A8AQSW-Fig.1
YB12E4-10A10AQSW-Fig.1
YB12E4-15A15AQS--Fig.1
YB12E4-20A20AQS--Fig.1
YB12D2-1A1AQSW-Fig.1
YB12D2-2A2AQSW-Fig.1
YB12D2-3A3AQSW-Fig.1
YB12D2-4A4AQSW-Fig.1
YB12D2-6A6AQSW-Fig.1
YB12D2-8A8AQSW-Fig.1
YB12D2-10A10AQSW-Fig.1
YB12D2-15A15AQS--Fig.1
YB12D2-20A20AQS--Fig.1
YB12D2-30A30AQS--Fig.1
YB12D3-1A1AQSW-Fig.1
YB12D3-2A2AQSW-Fig.1
YB12D3-3A3AQSW-Fig.1
YB12D3-4A4AQSW-Fig.1
YB12D3-6A6AQSW-Fig.1
YB12D3-8A8AQSW-Fig.1
YB12D3-10A10AQSW-Fig.1
YB12D3-15A15AQS--Fig.1
YB12D3-20A20AQS--Fig.1
YB12D4-30A30AQS--Fig.1

Medical equipment


Model No.Rated Current
@40°C

Terminal Options

Bleeder resistor(optional)

Medical equipment5

Leakage current 

250V/50Hz

Electrical

Schematic

Rated Voltage

(V)

Operating Frequency

(Hz)

YB12E4-1A1AQSW15<5μAFig.2115/250V50/60Hz
YB12E4-2A2AQSW15Fig.3
YB12E4-3A3AQSW15Fig.4
YB12E4-4A4AQSW15Fig.5
YB12E4-6A6AQSW15Fig.2
YB12E4-8A8AQSW15Fig.2
YB12E4-10A10AQSW15Fig.2
YB12E4-15A15AQS-15Fig.2
YB12E4-20A20AQS-15Fig.2
YB12D2-1A1AQSW15Fig.2
YB12D2-2A2AQSW15Fig.2
YB12D2-3A3AQSW15Fig.2
YB12D2-4A4AQSW15Fig.2
YB12D2-6A6AQSW15Fig.2
YB12D2-8A8AQSW15Fig.2
YB12D2-10A10AQSW15Fig.2
YB12D2-15A15AQS-15Fig.2
YB12D2-20A20AQS-15Fig.2
YB12D2-30A30AQS-15Fig.2
YB12D3-1A1AQSW15Fig.2
YB12D3-2A2AQSW15Fig.2
YB12D3-3A3AQSW15Fig.2
YB12D3-4A4AQSW15Fig.2
YB12D3-6A6AQSW15Fig.2
YB12D3-8A8AQSW15Fig.2
YB12D3-10A10AQSW15Fig.2
YB12D3-15A15AQS-15Fig.2
YB12D3-20A20AQS-15Fig.2
YB12D4-30A30AQS-15Fig.2


Mechanical Dimension



Insertion loss table(In 50ohm system according IEC/CISPR No.17)


-------common mode  -------differential mode

General purpose power supply filter 12 line below 30A
Long press to look detail
Long by picture save/share
图片展示

WeChat Subscription

图片展示

Wechat

SHENZHEN YANBIXIN TECHNOLOGY CO.,LTD    TEL:+86-755-27147102/27147103

SHENZHEN YANBIXIN TECHNOLOGY CO.,LTD

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了